2026-11-12
A dump truck operator notices that the first part of the lift is fast and strong, but the last part is slow and weak. The pump pressure is steady at 200 bar. The flow is steady at 60 liters per minute. The difference is not the pump. It is the way a set of Telescopic Cylinders distributes pressure across the stages. Each stage has a different bore, and the bore determines the area that the pressure acts on. The largest stage extends first because it has the largest area. The smallest stage extends last because it has the smallest area. This guide explains how the pressure is distributed, why the force and speed change from stage to stage, and what to verify before specifying a multi-stage cylinder.
A telescopic cylinder is a series of nested tubes. The largest tube is the outer barrel. The smallest tube is the inner ram. When oil enters the cylinder, it first fills the largest stage and pushes the largest tube out. Once that stage reaches the end of its stroke, the oil passes through a port in the piston and enters the next stage. The pressure is the same in all connected chambers, but the area that the pressure acts on is different for each stage. The force is the product of the pressure and the area. The speed is the flow divided by the area. Therefore, as the stages extend, the force decreases and the speed increases. The pressure does not change, but its effect changes because the area changes. In our factory, we design multi-stage Telescopic Cylinders with stage areas calculated for the required force profile. Jinan Huachen Industrial Co., Ltd. has been manufacturing hydraulic cylinders for over 15 years.
The redistribution is not a choice. It is a consequence of the geometry. The engineer can only choose how many stages to use and how large each stage should be. A five-stage cylinder has a large force at the first stage and a small force at the last stage. A three-stage cylinder has a smaller difference between the first and the last stage. The choice depends on the load profile.
The stepped bore is the internal profile of the nested tubes. Each stage has a piston at its base. The piston has a seal that separates the pressure chamber from the next stage. When the stage is fully extended, the piston uncovers a port that connects the pressure chamber to the next stage. The oil then flows into the next chamber and pushes the next stage out. The sequence is controlled by the port positions, not by an external valve. The table below shows the pressure and area at each stage of a five-stage cylinder at 200 bar.
| Stage | Bore diameter | Effective area | Pressure | Thrust force |
| 1 (largest) | 200 mm | 314 cm² | 200 bar | 628 kN |
| 2 | 170 mm | 227 cm² | 200 bar | 454 kN |
| 3 | 140 mm | 154 cm² | 200 bar | 308 kN |
| 4 | 110 mm | 95 cm² | 200 bar | 190 kN |
| 5 (smallest) | 80 mm | 50 cm² | 200 bar | 100 kN |
In our factory, we measure the bore and the port position on every stage before assembly. The port must be positioned so that it opens only when the previous stage is fully extended. If the port opens early, two stages can extend at the same time, and the cylinder can buckle. Jinan Huachen Industrial Co., Ltd. tests the extension sequence on a horizontal test bench before shipment.
The force and speed change in opposite directions. The force decreases as the area decreases. The speed increases as the area decreases because the same flow fills a smaller volume. In a dump truck application, the first stage lifts the loaded body slowly and with high force. The last stage moves quickly and with low force, which is acceptable because the load has already been discharged. In a crane application, the load remains constant, so the last stage may not have enough force to hold the load. The cylinder must be sized for the worst-case condition, which is the last stage. The table below shows the force and speed at each stage for a 60 liter per minute flow.
| Stage | Effective area | Flow | Extension speed | Thrust force at 200 bar |
| 1 (largest) | 314 cm² | 60 L/min | 0.32 m/min | 628 kN |
| 2 | 227 cm² | 60 L/min | 0.44 m/min | 454 kN |
| 3 | 154 cm² | 60 L/min | 0.65 m/min | 308 kN |
| 4 | 95 cm² | 60 L/min | 1.05 m/min | 190 kN |
| 5 (smallest) | 50 cm² | 60 L/min | 2.00 m/min | 100 kN |
Hydraulic engineer's note: The last stage is the critical stage for load holding. If the load is constant, the cylinder must be sized so that the last stage can hold the load at the maximum pressure. In our factory, we recommend that the customer provide the load at each part of the stroke so that we can calculate the required stage areas. Huachen provides the stage force calculation with each quotation.
The pressure distribution depends on the seals and the clearances between the stages. Each stage has a piston seal and a rod seal. If the piston seal leaks, the pressure drops before the next stage extends, and the sequence is delayed. If the rod seal leaks, oil bypasses to the outside, and the stage loses force. The clearance between the stages also matters. A large clearance allows the stage to tilt, which can damage the seal and create a leak path. The clearance must be small enough to guide the stage but large enough to allow thermal expansion. In our factory, we machine the stage tubes to an H8/f7 clearance and we use a wear ring on the piston to guide the stage. We also purge the cylinder before shipment to remove air. Air in the cylinder compresses and causes the stages to extend in an uneven sequence. Jinan Huachen Industrial Co., Ltd. performs a purge and a sequence test on every multi-stage cylinder.
The purge procedure is important for field installation. The installer should extend and retract the cylinder several times at low pressure to push the air out through the bleed port. The bleed port is located at the highest point of each stage. If the air is not removed, the cylinder will be spongy and the stages may not extend in the correct order.
The specification should include five items. The first is the load at each part of the stroke. The second is the available pump pressure and flow. The third is the number of stages and the bore of each stage. The fourth is the extension sequence. The fifth is the purge and test requirement. The verification should include three checks. The first is the stage force calculation. The second is the sequence test on a test bench. The third is the field purge and pressure test. In our factory, we provide the stage force calculation, the sequence test report, and the purge procedure with each cylinder. We also recommend that the customer verify the last stage force against the load before accepting the design. Jinan Huachen Industrial Co., Ltd. can provide a field commissioning service for critical installations.
We recommend that the engineer specify the stage areas rather than the stage diameters. The area is the parameter that determines the force. A cylinder with the correct diameter but the wrong wall thickness may have the wrong area, and the force will not match the calculation.
Telescopic Cylinders distribute hydraulic pressure across multiple stages through the stepped bore geometry and the port positions. The pressure is the same in all connected chambers, but the effective area decreases at each stage, so the force decreases and the speed increases as the stages extend. The stage areas must be selected for the load at each part of the stroke, and the last stage must be checked against the constant load if the application requires it. The seals, clearances, and purging determine whether the pressure distributes evenly and whether the stages extend in the correct sequence. The specification should include the load profile, the pump pressure and flow, the stage areas, the sequence, and the purge requirement. Jinan Huachen Industrial Co., Ltd. has been manufacturing hydraulic cylinders for over 15 years and provides full stage force calculation and sequence testing for our customers.